Download Raztec Sensors product catalogue guide reference instrument guide current sensing current sensor Air New Zealand Cargo, Canterbury Export Awards 2010 Raztec Sensors logo RoHS WEEE green environment friendly non-toxic leadfree Best of Sensors Expo 2006

RAZC-2-FL rugged, flying lead current transducer

Moulded sensor with flying lead termination.

RAZC-2-FL rugged, flying lead current transducer

Absolute Maximum Ratings (Ta=25C)

Parameter Symbol Value Unit
Operating Temperature TA -40 to +85 °C
Storage Temperature Tstg -65 to +150 °C
Supply Voltage Vs 8 V
Output sinking current Io 10 mA
Measured Current Im Limited only by conductor A

Characteristics

(TA = 25°C unless stated, VS = 5V)

Parameter Symbol Lower Limit Typical Upper Limit Unit
Supply Current Is     11 mA
Supply Voltage Vs 4.5 5.0 6.0 V
Current Range for < ±1% error (-25 to +85°C) Im ±80     A
Power-on settling time to 99% too     15 µs
Null Output (Vs = 5V) Vo 2.4 2.5 2.6 V
Transfer Function (per turn) ΔV/I 15.6 16 16.4 mV/A
Combined non-linearity and  hysteresis error (±100A, -25 to +85C)     0.5 1.5 %
Output error due to 5mm diameter wire position       ±0.1 %
Hysteresis (0 to 50AT) Hys   0.1   %
Null drift due to temperature change TCΔVo/Vo     ±0.25 mV/K
Gain change due to temperature change TCG -0.1 +0.1 0.18 %/K
Risetime 0 to 20AT at 20A/us tr   14   µs
Frequency Response f-3dB   35   kHz
Output resistance Ro   2 5

Datasheet