RAZCPC+Degauss Current Transducer
Calibrated super-precision model.

Absolute Maximum Ratings
|
Parameter |
Symbol |
Value |
Unit |
|
Operating Temperature |
TA |
-40 to +150 |
°C |
|
Storage Temperature |
Tstg |
-65 to +165 |
°C |
|
Supply Voltage |
Vs |
8 |
V |
|
Output Sinking Current |
Io |
10 |
mA |
|
Measured Current |
Im |
Limited only by conductor |
A |
Characteristics
(TA = 25°C unless stated, VS
= 5V)
|
Parameter |
Symbol |
Lower Limit |
Typical |
Upper Limit |
Unit |
|
Supply Current |
Is |
|
9.2
|
111 |
mA |
|
Supply Voltage |
Vs |
4.5 |
5.0 |
5.5 |
V |
|
Null Output (Vs = 5V) |
Vo |
2.490 |
2.5 |
2.510 |
V |
|
Transfer Function (per turn) RAZCPC100 |
ΔV/I |
98
|
100
|
102
|
mV/A |
|
Linear Current Range RAZCPC100 |
Im |
|
±20
|
|
A |
|
Linearity (±80%*Im) |
|
|
0.1
|
0.2
|
% |
|
Hysteresis (0 to 50%*Im) |
Hys |
|
0.0
|
10
|
mA |
|
Null drift due to temperature change |
TCΔVo/Vo |
|
±0.07 |
±0.15 |
mV/K |
|
Gain change due to temperature change |
TCG |
|
+0.05 *
|
|
%/K |
|
Risetime 0 to 20% of Im |
Tr |
|
15
|
|
µs |
|
Frequency Response |
f-3dB |
|
50 |
|
kHz |
|
Output Resistance |
R0 |
|
1 |
|
Ω |
|
Electrical Isolation |
Vd |
600 ** |
|
|
V |
|
Degauss coil turns |
|
|
30
|
|
|
|
Required deaguassing energy |
|
2.5 |
|
|
mJ |
* Tighter specification units available on request.
** Additional isolation can be provided by primary conductor insulation.
Datasheet
|